Cementeria di Monselice, Italy
Commissioned | 05/2006 |
Process | High-Dust |
Typical Operation
Flue gas | 320-330°C |
110.000 Nm³/h | |
Dust | 100 g/Nm³ |
Layers | 4 in operation |
NOx in | 1100-1300 mg/Nm³ |
NOx out | 200-400 mg/Nm³ |
NH₃ out | < 5 mg/Nm³ |
VOC reduction | 65-70% |
Fuel | Petcoke |
Proven reliability and uninterrupted long-term operation with dust cleaning tailored to cement applications.
The oldest catalytic elements have been in operation without requiring regeneration for several years. Since the lifetime of the elements can be extended through multiple regeneration, this is truly an economically attractive solution.